Engineered power infrastructure for mission-critical systems

Solution

Data Centers

Build end-to-end power visibility from 800 VDC facility busways and rack inputs to individual IT loads, while supporting high-density, resilient and serviceable data-centre architectures.

Operating priorities

Power visibility that supports better decisions.

The solution is shaped around availability, serviceability, measurement depth, remote access and the physical constraints of the deployment.

Relevant capabilities

  • AC PDUs from 16 A to 63 A and up to 48 outlets
  • DC PDUs with inputs up to 1000 A and branches up to 100 A
  • A/B automatic source transfer for single-corded equipment
  • OCP ORv3-compatible rack power-system configurations
  • 800 VDC AI/HPC busbar monitoring
  • Energy, environmental and commissioning-test infrastructure

Portfolio fit

Complete enterprise data-centre portfolio.

AC

AC Power Distribution Units

Rack input distribution across basic, metered, monitored, switched and switched-metered tiers, from single-phase 16 A to three-phase 63 A.

DC

DC Power Distribution Units

High-current DC distribution for telecom, HPC and AI infrastructure with per-branch protection and inlet/outlet telemetry.

kW

Energy Metering & Monitoring

AC and DC metering from facility feed to branch circuit for PUE, capacity planning and cost allocation.

ENV

Sensors & Environmental Monitoring

Rack-mount thermal, airflow, humidity, leak, contact and access sensors integrated with Zentronics controllers and PDUs.

1U

Rack Power Supply & 1U Power Systems

Centralised 1U/2U rack power conversion, battery management and distribution for enterprise, telecom and OCP environments.

OCP

OCP / V3 Power Shelf

Open Rack V3 rectifier shelves with front hot-swap PSUs, common bus-bar output and fleet-level PMBus / I²C telemetry.

Tap

800 VDC Rack Tap-off

Controlled, DC-protected rack drop from the overhead 800 VDC busway with local voltage, current and power metering.

800V

800 VDC Intelligent PDU

Rack-level 800 VDC distribution with per-branch DC protection, per-branch metering and keyed polarised outputs.

DC-DC

800 VDC → 48 V Sidecar Converter

Rack-adjacent DC-DC conversion from 800 VDC facility distribution to a 48 VDC compute bus, aligned to sidecar-rack topology.

800V

Busbar Power Monitoring — 800 VDC

Precision telemetry for high-density 800 VDC AI and HPC busways from facility perimeter to compute rack.

RLC

Intelligent Load Banks

Programmable resistive and RLC rack loads for commissioning, thermal simulation and system validation.

Infrastructure for modern compute

Coordinate distribution, conversion, visibility and validation.

Zentronics supports conventional enterprise racks through high-density AI clusters with AC PDUs, high-current DC distribution, OCP/V3 shelves, 800 VDC architectures, branch and busbar metering, environmental sensing and intelligent load banks.

Power path

Define the facility feed, busway, rack input, conversion, branch protection, outlets and redundancy architecture as one coordinated system.

Operational visibility

Combine electrical telemetry, environmental sensing, alarms, historical records and management integration to support capacity and availability decisions.

Commissioning

Use programmable loads and structured acceptance checks to validate power, cooling, controls and monitoring before compute deployment.

Zentronics brings in-house electrical, mechanical, firmware and manufacturing capability to standard and custom requirements. For AI data centres, current development focus includes 800 VDC tap-off, intelligent distribution, busbar measurement and rack-side conversion to 48 VDC.

Plan a data centers power solution.

Share your voltage, current, outlet, communication and mechanical requirements with the Zentronics engineering team.