Power path
Define the facility feed, busway, rack input, conversion, branch protection, outlets and redundancy architecture as one coordinated system.
Solution
Build end-to-end power visibility from 800 VDC facility busways and rack inputs to individual IT loads, while supporting high-density, resilient and serviceable data-centre architectures.
Operating priorities
The solution is shaped around availability, serviceability, measurement depth, remote access and the physical constraints of the deployment.
Portfolio fit
AC
Rack input distribution across basic, metered, monitored, switched and switched-metered tiers, from single-phase 16 A to three-phase 63 A.
DC
High-current DC distribution for telecom, HPC and AI infrastructure with per-branch protection and inlet/outlet telemetry.
kW
AC and DC metering from facility feed to branch circuit for PUE, capacity planning and cost allocation.
ENV
Rack-mount thermal, airflow, humidity, leak, contact and access sensors integrated with Zentronics controllers and PDUs.
1U
Centralised 1U/2U rack power conversion, battery management and distribution for enterprise, telecom and OCP environments.
OCP
Open Rack V3 rectifier shelves with front hot-swap PSUs, common bus-bar output and fleet-level PMBus / I²C telemetry.
Tap
Controlled, DC-protected rack drop from the overhead 800 VDC busway with local voltage, current and power metering.
800V
Rack-level 800 VDC distribution with per-branch DC protection, per-branch metering and keyed polarised outputs.
DC-DC
Rack-adjacent DC-DC conversion from 800 VDC facility distribution to a 48 VDC compute bus, aligned to sidecar-rack topology.
800V
Precision telemetry for high-density 800 VDC AI and HPC busways from facility perimeter to compute rack.
RLC
Programmable resistive and RLC rack loads for commissioning, thermal simulation and system validation.
Infrastructure for modern compute
Zentronics supports conventional enterprise racks through high-density AI clusters with AC PDUs, high-current DC distribution, OCP/V3 shelves, 800 VDC architectures, branch and busbar metering, environmental sensing and intelligent load banks.
Define the facility feed, busway, rack input, conversion, branch protection, outlets and redundancy architecture as one coordinated system.
Combine electrical telemetry, environmental sensing, alarms, historical records and management integration to support capacity and availability decisions.
Use programmable loads and structured acceptance checks to validate power, cooling, controls and monitoring before compute deployment.
Zentronics brings in-house electrical, mechanical, firmware and manufacturing capability to standard and custom requirements. For AI data centres, current development focus includes 800 VDC tap-off, intelligent distribution, busbar measurement and rack-side conversion to 48 VDC.
Share your voltage, current, outlet, communication and mechanical requirements with the Zentronics engineering team.